GB - 17
5.1.1 keyboard
When switching on KEB COMBIVERT R5 the value of parameter CP.1 is
displayed. (change-over of the keyboard function see Drivemode)
Principally during a change, parameter values are immediately accepted and
stored non-volatile. However, with some parameters it is not useful that the
adjusted value is accepted immediately. When this type of parameter is changed
a point appears behind the last digit.
If a malfunction occurs during operation, the actual display is overwritten by the
alarm message. The alarm message in the display is reset by ENTER.
With ENTER only the error message in the display is reset. In order to reset the
error itself, the cause must be removed or a power-on reset must be made. In
the status display (CP. 1) the error will still be shown.
Operation of the Unit
The function key is
used to change between
parameter value and
parameter number.
With UP and DOWN the
value of the parameter
number is increased/
decreased with
changeable parameters.
The adjusted value
is accepted and non-
volatile stored with
ENTER.
Error