P30UDP interface: Guidelines
UDP Programmers Guide V2.01
12
© KEBA
Whitelist Operating status State Plug AuthON Authreq
Empty idle 1 3 0 0
Empty plugged but not charging 2 7 0 0
Empty charging 3 7 0 0
Not empty idle and locked 1 3 1 1
Not empty unlocked and not charging 1 3 1 0
Not empty
unlocked and plugged but not
charging
2 7 1 0
Not empty unlocked and charging 3 7 1 0
The following can be concluded for all device types listed as P30 c-series: If
the field “AuthON” is set to “0”, then the authorization function is disabled.
2.4.2 P30 x-series
P30 x-series features a web interface with a dedicated setting for the autho-
rization function. This function is governed by an additional circuit board
called “COM-module” which also houses the WiFi components. The RFID
authorization can be deactivated even though the whitelist of the charging
station is not empty.
P30 x-series will behave like P30 c-series after a restart until the COM-mod-
ule is ready (~ 5 min after restart). The data shown in the following table can
be acquired using the command report 2.
Whitelist Operating status State Plug AuthON Authreq
Empty idle 1 3 0 0
Empty plugged but not charging 2 7 0 0
Empty charging 3 7 0 0
Empty
idle and locked (cannot be un-
locked since whitelist is empty)
1 3 1 1
Not empty idle 1 3 0 0
Not empty plugged but not charging 2 7 0 0
Not empty charging 3 7 0 0
Not empty idle and locked 1 3 1 1
Not empty unlocked and not plugged 1 3 1 0
Not empty
unlocked and plugged but not
charging
2 7 1 0
Not empty unlocked and charging 3 7 1 0
The following can be concluded for all device types listed as P30 x-series: If
the field “AuthON” is set to “0”, then the authorization function is disabled.