REMOTE SELECTION BUTTON5.9
9.
Short Press: Panel /Gun Remote / Hand remote selection. If remote auto recognition is
selected ON (see P65 panel menu) only those remote controls which can be found are
selected.
Long Press: CH remote function ON/OFF. Gun remote or Hand remote control must be rst
selected before CH remote function can be selected ON/OFF. When active, memory channels
are selectable from the remote control device.
POWER ENCODER POTENTIOMETER5.10
10.
The power encoder knob allows adjustment of the wire feed speed or power in either Basic,
Synergic and Pulse Mig/Mag process. MMA current level is also adjusted here if the process
licence is active. Adjustments can be made before or during the arc process. This control also
adjusts additional parameter values when selected.
ARC LENGTH/VOLTAGE/ADJUSTMENT POTENTIOMETER5.11
11.
Arc length, voltage and parameter adjustments can be made using this knob. Adjustments
can be made before or during welding.