EN
1.3.2 Control panel
P1 P2 P3
P4 P5
P1 Left display (gouging current or name of adjustable parameter)
P2 Indicator lights for the current area
P3 Right display (gouging voltage or value of adjustable parameter)
P4 Setup button
P5 Control knob (gouging current adjustment, factory reset)
2. INSTALLATION
2.1 POSITIONING OF THE MACHINE
Place the machine on a rm, dry and level surface. Where possible, do not allow dust or other
impurities to enter the machines cooling air ow. Preferably site the machine above oor level;
for example on a suitable carriage unit.
Notes for positioning the machine
• The surface inclination should not exceed 15 degrees.
• Ensure the free circulation of the cooling air. There must be at least 20 cm of free space in
front of and behind the machine for cooling air to circulate.
• Protect the machine against heavy rain and direct sunshine.
NOTE! The machine should not be operated in the rain as the protection class of the machine, IP23S,
allows for outside preserving and storage only.
NOTE! Never aim metallic grinding spray/sparks towards the equipment.
5
KempGouge ARC 800 / © Kemppi Oy / 1117