2 Base Matrix Configuration
132 Keysight 34934A User’s Guide
Note that each row signal (R1 through R8 (H,L) is routed out on two pins on the
extension headers. You can make row signal connections to either row (upper,
lower) of the connector.
If you are going create an expanded-row matrix using multiple modules and
terminal blocks, plan your wiring placement for each terminal block carefully, to
allow for a daisy-chain interconnection between terminal blocks—in addition to
any row wiring you may connect to the expansion headers. This interconnection is
illustrated in Arranging Multiple 34934A Modules with Terminal Blocks” on
page 215.
Configuring an 8x32 Matrix using a Configuration Block
34934C-002 Configuration Block: Layout
This configuration block is labeled with the model number and the abbreviated
module name.
R4H 15 R4H 16 R8H 15 R8H 16
R4L 17 R4L 18 R8L 17 R8L 18
IL1 19 IL2 20 IL3 19 IL4 20
Header J24 Header J25
Description Pin Description Pin Description Pin Description Pin