282 Keysight InfiniiVision 1200 X-Series and EDUX1052A/G Oscilloscopes User's Guide
25 CAN Triggering and Serial Decode
Types of Frames Active error frames are CAN frames in which a CAN node recognizes an error
condition during a data or remote frame and issues an active error flag.
A partial frame occurs when the oscilloscope detects any error condition during
a frame that is not followed by an active error flag. Partial frames are not
counted.
Counters The FRAMES counter gives the total number of completed remote, data,
overload, and active error frames.
The OVLD counter gives the total number of completed overload frames and
their percentage of the total number of frames.
The ERR counter gives the total number of completed active error frames and
their percentage of the total number of frames.
The LOAD (bus load) indicator measures the percentage of time the bus is
active. The calculation is done on 330 ms periods, approximately every 400 ms.
Example: If a data frame contains an active error flag, both the FRAMES counter
and the ERR counter will be incremented. If a data frame contains an error that is
not an active error it is considered a partial frame and no counters are
incremented.