EasyManua.ls Logo

Keysight E6961A User Manual

Keysight E6961A
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Keysight E6961A Automotive
Ethernet Transmit
Compliance Solution
User Guide and
Method of
Implementation

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Keysight E6961A and is the answer not in the manual?

Keysight E6961A Specifications

General IconGeneral
BrandKeysight
ModelE6961A
CategoryTest Equipment
LanguageEnglish

Summary

Overview

Introduction

Provides context on BroadR-Reach specifications and the purpose of the solution.

Installing the Compliance Test Solution Software

Step-by-step guide for downloading and installing the test application software.

Installing the License Key

Instructions on how to activate the software license using a provided license code.

Preparing to Take Measurements

Essential calibration steps for the oscilloscope and probes before running tests.

General Test Setup

Describes the necessary hardware connections and configurations for various test modes.

Starting the Automotive Ethernet Compliance Test Solution Software

Guides users on launching the compliance test application from the oscilloscope.

Test Mode 1. Output Droop Tests

Details for performing transmitter output droop measurements according to standards.

Test Mode 2. MASTER Clock Frequency and Jitter Tests

Procedures for testing clock frequency and jitter in MASTER mode.

Test Mode 3. SLAVE Transmit Clock Frequency and Jitter Tests

Procedures for testing clock frequency and jitter in SLAVE mode.

Test Mode 4. Transmitter Distortion and MDI Return Loss Tests

Covers tests for signal distortion and MDI return loss.

Viewing the Test Report

Explains how to access, interpret, and generate compliance test reports.

Reference Documents

Lists relevant specifications and standards for BroadR-Reach compliance.

Setting Up the N5395C Ethernet Transmitter Test Fixture

Introduction

Introduces the N5395C Ethernet Transmitter Test Fixture and its components.

Jumper Settings

Details the jumper configurations on the test fixture for different frequency settings.

Configure External Instruments

Introduction

Explains the necessity and process of configuring external test instruments.

Configure External Instruments

Step-by-step guide to identify and set up external instruments like AWGs and analyzers.

External Instrument Calibration

Introduction

Overview of the calibration process for external instruments.

Calibrating the AWG

Steps for calibrating the Arbitrary Waveform Generator (AWG) used as a signal source.

Calibrating the ENA

Steps for calibrating the ENA (Vector Network Analyzer) for return loss measurements.

Using the E6960-66600 Frequency Divider Board

Introduction

Introduces the frequency divider board and its purpose.

Static-safe Handling Procedures

Guidelines for safely handling electronic components, including the divider board.

Frequency Divider Board Test Setup

Describes the physical connections required for the frequency divider board.

Connector Description

Details the various connectors available on the frequency divider board.

Jumper Settings

Explains the function of jumpers on the frequency divider board.

DIP Switch Description

Describes the configuration options available through the DIP switches on the frequency divider board.

Related product manuals