[SOURce:]ARB:SEQuence:STEP:CURRent:EXPonential:STARt:TIMe <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:EXPonential:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:EXPonential:STARt:TIMe<value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:EXPonential:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:EXPonential:STARt:TIMe<value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:EXPonential:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:EXPonential:STARt:TIMe<value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:EXPonential:STARt:TIMe? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the delay in seconds after the trigger is received, but before the exponential waveform
occurs for Arb sequence steps.
Parameter Typical Return
0 262.144 | MIN | MAX, *RST 0 <start time>
Step 0 - 99, *RST 0 (none)
Programs a start time for the current Arb: ARB:CURR:EXP:STAR:TIM 1,(@1)
Programs a start time for the voltage Arb: ARB:VOLT:EXP:STAR:TIM 1,(@1)
Programs a start time for the power Arb: ARB:POW:EXP:STAR:TIM 1,(@1)
Programs a start time for the resistance Arb: ARB:RESISTANCE:EXP:STAR:TIM 1,(@1)
Programs a start time for step 0: ARB:SEQ:STEP:CURR:EXP:STAR:TIM 1, 0,(@1)
[SOURce:]ARB:CURRent:EXPonential:TCONstant <value>, (@<chanlist>)
[SOURce:]ARB:CURRent:EXPonential:TCONstant? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:VOLTage:EXPonential:TCONstant <value>, (@<chanlist>)
[SOURce:]ARB:VOLTage:EXPonential:TCONstant? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:POWer:EXPonential:TCONstant <value>, (@<chanlist>)
[SOURce:]ARB:POWer:EXPonential:TCONstant? [MIN|MAX,] (@<chanlist>)
[SOURce:]ARB:RESISTANCE:EXPonential:TCONstant <value>, (@<chanlist>)
[SOURce:]ARB:RESISTANCE:EXPonential:TCONstant? [MIN|MAX,] (@<chanlist>)
Specifies the time constant of the exponential curve.
[SOURce:]ARB:SEQuence:STEP:CURRent:EXPonential:TCONstant <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:EXPonential:TCONstant ? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:EXPonential:TCONstant <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:EXPonential:TCONstant ? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:EXPonential:TCONstant <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:EXPonential:TCONstant ? [MIN|MAX,] <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:EXPonential:TCONstant <value>, <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:EXPonential:TCONstant ? [MIN|MAX,] <step#>, (@<chanlist>)
Specifies the time constant of the exponential curve for Arb sequence steps.
Parameter Typical Return
0 262.144 | MIN | MAX, *RST 1 <time constant>
5 SCPI Programming Reference
192 Keysight N6700C Operating and Service Guide