[SOURce:]
STEP
:TOUTput 0|OFF|1|ON, (@chanlist) Specifies whether a trigger is generated when a step occurs.
[SOURce:]
VOLTage
[:LEVel]
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the output voltage.
:TRIGgered
[:AMPLitude] <value>, (@chanlist) Sets the triggered output voltage.
:BWIDth
[:RANGe] LOW|HIGH1|2|3, (@chanlist) Sets the voltage bandwidth. (N678xA SMU)
:LEVel LOW|HIGH1|2|3, <frequency>, (@chanlist) Sets the bandwidth frequency. (N678xA SMU)
:INHibit
:VON
[:LEVel] <value>, (@chanlist) Current will sink if voltage is > voltage-on level. (N679xA)
:MODE LATChing|LIVE|OFF Sets the under-voltage inhibit mode. (N679xA)
:LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the positive voltage limit. (N678xA SMU)
:COUPle 0|OFF|1|ON, (@chanlist) Sets the voltage limit tracking state. (N6784A)
:NEGative
[:IMMediate]
[:AMPLitude] <value>, (@chanlist) Sets the negative voltage limit. (N6784A)
:MODE FIXed|STEP|LIST|ARB, (@chanlist) Sets the transient mode.
:PROTection
[:LOCal]
[:LEVel] <value>, (@chanlist) Sets the over-voltage protection level.
:DELay
[:TIME] <value>, (@chanlist) Sets the over-voltage protection delay. (N678xA SMU, N6783A)
:REMote
[:POSitive]
[:LEVel] <value>, (@chanlist) Sets the positive remote OV protection. (N678xA SMU, N679xA)
:NEGative
[:LEVel] <value>, (@chanlist) Sets the negative remote OV protection. (N6784A)
:TRACking
[:STATe] 0|OFF|1|ON, (@chanlist) Enables/disables tracking over-voltage protection. (Option J01)
:OFFSet <value>, (@chanlist) Sets the tracking OVP offset. (Option J01)
:RANGe <value>, (@chanlist) Sets the output voltage range.
:RESistance
[:LEVel]