Verification kits 
All Keysight verification kits include: 
•
  Precision Z0 airline or match thru 
•
  Mismatched airline or mismatch thru 
•
  Fixed attenuators (except 85059V) 
•
  Traceable measured data and uncertainties 
 
85051B 45 MHz to 18 GHz 7 mm kit 
Includes attenuators, airline and mismatch airline with data on a USB drive for use in confirming 
calibrated system performance, traceable to national standards. Test procedure is provided in the service 
manual. 
85053B 300 kHz to 26.5 GHz 3.5 mm kit 
Includes attenuators, airline and mismatch airline with data on a USB drive for use in confirming 
calibrated system performance, traceable to national standards. Test procedure is provided in the service 
manual. 
85055A 300 kHz to 18 GHz Type-N kit 
Includes attenuators, airline and mismatch airline with data on a USB drive for use in confirming 
calibrated system performance, traceable to national standards. Test procedure is provided in the service 
manual. 
85057B 45 MHz to 50 GHz 2.4 mm kit 
Includes attenuators, airline and mismatch airline with data on a USB drive for use in confirming 
calibrated system performance, traceable to national standards. Test procedure is provided in the service 
manual. 
85058V 45 MHz to 67 GHz 1.85 mm kit 
Includes attenuators, match thru and mismatch thru with data on a USB drive for use in confirming 
calibrated system performance, traceable to national standards. Test procedure is provided in the service 
manual.   
Find us at www.keysight.com  Page 25 
Learn more at: www.keysight.com 
For more information on Keysight Technologies’ products, applications or services, 
please contact your local Keysight office. The complete list is available at: 
www.keysight.com/find/contactus 
This information is subject to change without notice. © Keysight Technologies, 2019, Published in USA, February 12, 2019, 5992-2823EN 
PC Requirements for USB VNA control 
Requirement  For P937xA Series 
Windows 7 or Windows 10 (64-bit) 
Intel i5 6
th
 generation or newer/Intel Xeon E3 v3 or newer 
4 GB minimum, 16 GB recommended 
2 GB available disk space minimum 
USB 3.0 port directly connected to Intel chipset 
Literature Information 
Keysight P937xA Series USB Vector Network Analyzer – Data Sheet, 5992-2765EN 
Keysight P500xA Series USB Vector Network Analyzer – Data Sheet, 5992-3606EN 
Keysight Vector Network Analyzer – Selection Guide, 5980-7603EN 
Electric Calibration (ECal) Modules – Technical Overview, 5963-7343E 