EasyManua.ls Logo

Kicker LX Series - Page 36

Kicker LX Series
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36English
For multiple amplifier installations where
distribution blocks are used, each amplifier
should have its proper-rated fuse, or
breaker, installed between the amplifier and
the distribution block within eighteen inches
of the block, or on the distribution block if it
provides for fusing. The primary power wire
should also be fused between the battery
and distribution block, within eighteen
inches of the battery’s positive terminal, with
a fuse or breaker rated at least to the sum
of the individual amplifiers fuse values, but
doesn’t exceed the capacity of your wiring.
12V
external fuse
to amplifiers
≤18”
(45cm)
external fuse
≤18”
(45cm)
external fuse
power distribution block
battery
≤18”
(45cm)