Chapter 6 List of Parameters
74
Function
code
Name Descriptions Unit
Factory
setting
Modif
.
Setting
range
3: User menu (reserved)
4: proofreading menu
b4.12
b4.15
Reserved - - - - 0 65535
b4.16
Standard / High frequency
switching
0: Standard frequency
1: High frequency
1 0 X 0 1
b4.17 Fast current limit enable 0: closed
1: enable
1 0 X 0 1
b4.18
Motor selection
0
:
Motor 1
1
:
motor 2
1 0 X 0 1
b5 Motor 2 parameters
b5.00 Asynchronous motor 2
rated power
0.2 999.9KW 0.1 0 X 2 9999
b5.01 Asynchronous motor 2
rated voltage
0 Inverter Rated voltage 1 0 X 0 999
b5.02 Asynchronous motor 2
rated current
0.1 999.9A 0.1A Determined
by model
X 1 9999
b5.03 Asynchronous motor 2
rated frequency
1.00 1000.00Hz 0.01Hz Determined
by model
X 100
30000
b5.04 Asynchronous motor
2pole number
2 24 1 4 X 2 24
b5.05 Asynchronous motor 2
rated speed
0 60000RPM 1RPM 1440RPM X 0 60000
b5.06 Asynchronous motor 2
stator resistance %R1
0.00% 50.00% 0.01% Determined
by model
X 0 5000
b5.07 Asynchronous motor 2
leakage inductance %X
0.00% 50.00% 0.01% Determined
by model
X 0 5000
b5.08 Asynchronous motor 2
rotor resistance %R2
0.00% 50.00% 0.01% Determined
by model
X 0 5000
b5.09 Asynchronous motor 2
mutual inductance %Xm
0.0% 2000.0% 0.1% Determined
by model
X 0 20000
b5.10 Asynchronous motor 2
no-load current I0
0.1 999.9A 0.1A Determined
by model
X 1 9999
b5.11 Asynchronous motor 2
parameter auto-tuning
0: disable
1: Stationary auto-tuning
(Start auto-tuning to a standstill motor)
2: Rotating auto-tuning
3: Reserved
(calculated by nameplate setting)
1 0 X 0 3
b5.12 Asynchronous motor 2
overload protection
coefficient
20.0% 110.0% 0.1% 100.0% X 200 1100
b5.13 Asynchronous motor 2
overload protection time
0.0 6000.0; 0.0: Calculate the overload
according to the internal overload curve