Chapter 6 List of Parameters
75
Function
code
Name Descriptions Unit
Factory
setting
Modif
.
Setting
range
b5.14 Asynchronous motor 2
oscillation inhibition
coefficient
0 255 1 10 O 0 255
b5.15 Synchronous motor 2
rated power
0.4 999.9KW 0.1KW Determined
by model
X 4 9999
b5.16 Synchronous motor 2
rated voltage
0 inverter rated voltage (F82.04)
2 series: 220V
4 series: 380V
1V Determined
by model
X 0 999
b5.17 Synchronous motor 2
rated current
0.1 999.9A 0.1A Determined
by model
X 1 9999
b5.18 Synchronous motor 2
rated frequency
1.00 1000.00Hz
(Remark: Pole number and rated
frequency can be calculated from each
other by only setting one of them.)
0.01Hz Determined
by model
X 100
100000
b5.19 Synchronous motor 2
pole-pair number
1 40 1 2 X 1 40
b5.20 Synchronous motor 2
rated speed
0 60000RPM 1RPM 1500RPM X 0 60000
b5.21 Synchronous motor 2
stator resistance
0.00% 50.00% 0.01% Determined
by model
X 0 5000
b5.22 Synchronous motor 2
straight shaft inductance
0.0 999.9mH 0.1mH Determined
by model
X 0 9999
b5.23 Synchronous motor 2
quadrature axis
inductance
0.0 999.9mH 0.1mH Determined
by model
X 0 9999
b5.24 Back potential constant of
synchronous motor
1000V/1000RPM 1 150 X 0 1000
b5.25 Synchronous motor 2
position identification
Identification starts from 0 to 1 and
automatically changes to 0 when the
recognition ends.
1 0 X 0 1
b5.26 Synchronous motor 2
identification current
0 30% Motor Rated current 1 10 X 0 30
b5.27 Synchronous motor 2
initial angle
0 FFFFH 1 0 X 0 FFFF
b5.28 Synchronous motor 2 Z
phase pulse initial angle
0 FFFFH 1 0 X 0 FFFF
b5.29 Synchronous machine 2
over load protection
coefficient
20.0% 110.0%
Set the action level (%) motor rated
current / inverter rated current 100
Low speed compensation actual action
level set action level (output
frequency / 30HZ 45 + 55)
Overload protection actual conversion
current sampling current / overload
protection action level
0.1% 100.0% X 200 1100