79
RO-Compact 2:
FLOW DIAGRAM
RO COMPACT 2
MV 1
MV 2
P1
Resevoir
Dyse
afløb
LSH
LSM
Membran
LSL
9
liter
ps
DWG NAME
ORIGINALLY DRAWN BY DATE
MATERIAL
MANAGER
SIZE SCALE SHEET
LAST MODIFIED BY DATE
DWG REV
FLOW - DIAGRAM
RO-COMPACT 2
Allan Herold/Søren Hansen 05/09-2012
COSTUMER
-
-
1 OF 1
B
Allan Herold 09-11-2016
ps
= flow control/nozzle
= Solenoid Valve
= Drain
= Pump
= Pressure switch
= Check valve
= Flow direction
P2
FS
fs
= flow switch
RO-Compact 2 no bypass:
FLOW DIAGRAM
RO COMPACT 2 without bypass
MV 1
P1
Resevoir
Dyse
afløb
LSH
LSM
Membran
LSL
18,2
liter
ps
DWG NAME
ORIGINALLY DRAWN BY DATE
MATERIAL
MANAGER
SIZE SCALE SHEET
LAST MODIFIED BY DATE
DWG REV
FLOW DIAGRAM
RO-COMPACT 2 NO BYPASS
Allan Herold/Søren Hansen 05/09-2012
COSTUMER
-
-
1 OF 1
B
Allan Herold 09/11-2016
ps
= flow control/nozzle
= Solenoid Valve
= Drain
= Pump
= Pressure switch
= Check valve
= Flow direction
P2
FS
fs
= flow switch
Nozzle
Drain
Nozzle
Drain
Membrane
Membrane