REMOVING AN INDUCTION ELEMENT ASSEMBLY
1. Unplug cooktop or disconnect power.
2. Remove the cooktop glass from the cooktop
(see page 4-2 for the procedure).
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Left Induction Elements
3. Remove the screws from the left or right
induction element assembly mounting plate
(see the right photos).
Right Induction Elements
Left Induction Element
Mounting Plate Screws (3)
Right Induction Element
Mounting Plate Screws (4)