— 21 —
TABLE INSPECTION FOR ELECTRC CHAIN HOISTS
Item
Normal Service
Heavy Service Severe Service
Visual
Monthly
Record
Yearly
Visual
Weekly
Record
Semiannually
Visual
Daily
Record
Quarterly
Electrical apparatus for signs of pitting or any
deterioration of visible controller contacts (see 5-3.g)
-
*
-
*
-
*
Evidence of damage of supporting structure or trolley,
if used
-
*
-
*
-
*
Warning label
-
*
-
*
-
*
End connections of load chain
-
*
-
*
-
*
5-4. Occasionally Used Hoists
(a) A hoist which has been idle for a period of 1 month or more, but less than 1 year, shall be given an
inspection conforming with the requirements of Sec. 5-2 before it is placed in service.
(b) A hoist which has been idle for a period of 1 year shall be given an inspection conforming with the
requirements of Sec. 5-3 before it is placed in service.
5-5. Inspection Record
(a) We recommend that dated inspection reports and records be maintained at time intervals specified in
Sec.5-1 (b) (2). We suggest strongly that records are stored where they be available to authorized persons.
(b) We suggest strongly that a long-range chain inspection program be established and include records of
examination of chains removed from service so a relationship could be established between visual
observation and actual condition of the chain.