Model : K1-22E/28E/34E/40E
(Wall Hung type & Indirectly Water heater
& Combination boiler)
NaturalGas(NG
)
– Factory Default
LiquidPropaneGas(LP
)
– Field-replaceable
 (Refertothegasconversionmanual.)
Manual
WARNING
ReadtheInstallationManualcarefullyandbesurethatyourcombinationboilerhasproperlyassembled,
installedandmaintained.Failuretofollowtheseinstructionsexactlycouldresultinareorexplosion,
seriousbodilyinjuryand/orpropertydamage.
Thisproductmustbeinstalledandservicedbyalicensedplumber,alicensedgastter,oraprofessional
technicianinaccordancewithalllocalcodes.
Improperinstallationand/oroperationbyanunqualiedpersonwillvoidthewarranty.
Donotstoreorusegasolineorotherammablevaporsandliquidsinthevicinityofthisoranyotherappliance.
WHATTODOIFYOUSMELLGAS
· Donottrytolightanyappliance.
· Donottouchanyelectricalswitch;donotuseanyphoneinyourbuilding.
· Immediatelycallyourgassupplierfromaneighbor’sphone.Followthegassupplier’sinstructions.
· Ifyoucannotreachyourgassupplier,calltheredepartment.
Installationandservicemustbeperformedbyaqualiedinstaller,serviceagencyorthegassupplier.
Iftheinformationinthese instructions are not followed exactly, a re or explosion mayresultcausingproperty
damage,personalinjuryordeath.
K1-22E/28E/34E/40E COMBINATION BOILER
ۣૐ
۞ইૐ઺Ҵ
ೠҴ࢑সӏѺ ಿ૕҃৔మ
<유럽-CE 인증> <터키-TSE 인증> <러시아-GOST R 인증>
<러시아-CTR 인증> <카자흐스탄-GOT 인증> <우크라이나-GOST 인증>
<관세동맹국-EAS 인증> <미국-ETL 인증> <미국-Energy Star 인증>
<미국-NSF 372 인증> <미국-NSF 5 인증> <미국-SQAMD 인증>
<미국-ASME H 인증><미국-ASME HLW 인증>
<국제표준규격>
<일본 JIA 인증>
<CTI 인증> <AMCA 인증>
<중국 인증>
<북미 인증>
<ASME 인증> <AHRI 550/590인증> <AHRI 410인증>

Questions and Answers

  • M
    Madison SmithSep 12, 2025
    What to check if Kiturami K1-22E showing 'Burner Limit Switch Abnormality'?
    • J
      jamiemurphySep 12, 2025
      If your Kiturami Boiler displays a 'Burner Limit Switch Abnormality', check if the minimum capacity is set too low. Also, verify if the high-efficiency pump speed is set properly or too low.
  • B
    Brenda LoganSep 14, 2025
    How to troubleshoot 'Pressure Sensor Abnormality' on Kiturami K1-22E?
    • J
      John BlackSep 15, 2025
      To troubleshoot a 'Pressure Sensor Abnormality' on your Kiturami Boiler, start by checking the water pressure sensor. If the issue persists, contact technical support.

Summary

Safety Information

Product Information

Technical Specifications Overview

Comprehensive technical data and performance metrics for boiler models.

Before Installation

Electrical Supply and Safety

Requirements for electrical connection, grounding, and isolation.

Gas Supply Connection Standards

Guidelines for safe and compliant gas supply connection.

Condensate Drain System

Detailed instructions for installing the condensate drain pipe.

Minimum Clearances and Flue Positioning

Required space and flue terminal placement rules.

Horizontal Coaxial Flue Fitting

Guide to installing the horizontal coaxial flue system.

Installation

Boiler Electrical Connections

Guidance for safe and compliant electrical installation.

Commissioning

Boiler Commissioning Procedure

Step-by-step guide for the commissioning process.

Gas Settings and Combustion Analysis

Procedures for setting gas type and measuring combustion.

Gas Conversion Procedures

Steps for converting the boiler between gas types.

Natural Gas to Propane Conversion

Detailed guide for converting from Natural Gas to Propane.

Boiler Operation

Troubleshooting

Boiler Error Code Reference

List of error codes and their corresponding remedies.

Kiturami K1-22E Specifications

General IconGeneral
BrandKiturami
ModelK1-22E
CategoryBoiler
LanguageEnglish