7. If something does not work
7.1. Error indication on the display
Repair and maintenance is to be carried out exclusively by Klafs' service personnel or
by personnel expressly authorized by Klafs!
The error message appears in the two right digits
of the bathing time indicator (e.g. 92).
The Service symbol
flashes together with the
error message.
As long as the Service symbol
flashes, you
are able to operate the control system.
The error message appears alternately with the
bathing program.
No. Error Error elimination
85 Line break in the motherboard/display
printed circuit board.
86 Line break in the infrared temperature sensor.
87 Short circuit in the infrared temperature
sensor.
88 Heating foil defect.
Remove power from the control system.
Do not use the cabin!
' Inform Klafs Service.
95 Line break in the actual temperature sensor.
96 Line break in the heater temperature sensor.
97 Safety temperature limiter (STL) interrupted.
98 Short circuit in the actual temperature sensor.
99 Short circuit in the heater temperature sensor.
92 Maintenance necessary - decalcify the
evaporator.
Decalcify the evaporator unit.
' See Section 8.1.

Table of Contents