GENERAL SPECIFICATIONS
Klein Tools MM700 is an automatically ranging true root mean square
(TRMS) digital multimeter that measures AC/DC voltage, AC/DC current,
and resistance. It can also measure temperature, capacitance, frequency,
duty-cycle, test diodes and continuity.
Operating Altitude: 6562 ft. (2000m)
Relative Humidity: <90% non-condensing
Operating Temp: 14°F to 122°F (-10°C to 50°C)
Storage Temp: -4°F to 140°F (-30°C to 60°C)
Accuracy: Values stated at 65°F to 83°F (18°C to 28°C)
Temp Coefcient: 0.1 x (Quoted Accuracy) per °C above
28°C or below 18°C, corrections are required when ambient
working temp is outside of Accuracy Temp range
Dimensions: 7.02" x 3.54" x 2.10" (178.3 x 89.9 x 53.3 mm)
Weight: 14.6 oz. (414 g)
Calibration: Accurate for one year
Standards: Conforms to: UL STD 61010-1, 61010-2-030,
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-030, 61010-2-033.
IEC EN 61010-1, 61010-2-030,
61010-2-033, 61326-1.
Pollution degree: 2
Accuracy: ± (% of reading + # of least significant digits)
Drop Protection: 6.6 ft. (2m)
Ingress Protection: IP42 (except test lead jacks, see WARNINGS)
Safety Rating:
CAT IV 600V, CAT III 1000V, Class 2,
Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s
low-voltage MAINS installation.
Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
RESISTANCE (AUTO-RANGING)
Function Resolution Accuracy
400.0Ω 0.1Ω
±(1.5% + 5 digits)
4.000kΩ
40.00kΩ 10Ω
400.0kΩ 100Ω
4.000MΩ 1kΩ
±(2.0% + 10 digits)
40.00MΩ 10kΩ
Maximum Input: 600V DC or 600V AC RMS
MM700-1390112ART.indd 2 9/21/2015 2:44:46 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools MM600 and is the answer not in the manual?

Klein Tools MM600 Specifications

General IconGeneral
Product typeDigital multimeter
Product colorBlack, Orange
AC current range0 - 10 A
DC voltage range0 - 1000 V
Measuring categoryCAT III 1000V, CAT IV 600V
Placement supportedHandheld multimeter
Temperature measurement range-18 - 538 °C
International Protection (IP) codeIP42
Battery typeAAA
Power sourceBattery
Number of batteries supported2
Carrying caseYes
Weight and Dimensions IconWeight and Dimensions
Depth178 mm
Width90 mm
Height53 mm
Weight408 g

Related product manuals