3
ELECTRICAL SPECIFICATIONS
VOLTAGE (AUTO-RANGING)
Function Range Resolution Accuracy (
50–60 Hz
)
AC Voltage
(V AC)
4.000V 1mV ±(1.0% + 5 digits)
40.00V 10mV ±(1.2% + 5 digits)
400.0V 100mV
±(1.5% + 5 digits)
1000V 1V
DC Voltage
(V DC)
400.0mV 0.1mV ±(1.0% + 8 digits)
4.000V 1mV
±(1.0% + 3 digits)40.00V 10mV
400.0V 100mV
1000V 1V ±(1.2% + 3 digits)
Input Impedance: 10MΩ
Frequency Range: 50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
CURRENT (AUTO-RANGING)
AC Current
(μA and mA)
400.0μA 0.1μA
±(1.5% + 3 digits)
4000μA 1μA
40.00mA 10μA
400.0mA 100μA
10.00A 0.01A ±(2.0% + 5 digits)
DC Current
(μA and mA)
400.0μA 0.1μA
±(1.0% + 3 digits)
4000μA 1μA
40.00mA 10μA
400.0mA 100μA
10.00A 0.01A ±(1.5% + 3 digits)
Overload Protection: 500mA / 1000V and 10A / 1000V Fuses
Frequency Range: 50 to 400Hz
Maximum Input: µA/mA setting: 400mA AC RMS / DC
10A setting: 10A AC RMS / DC
RESISTANCE (AUTO-RANGING)
Function Resolution Accuracy
400.0Ω 0.1Ω
±(1.5% + 5 digits)
4.000kΩ
40.00kΩ 10Ω
400.0kΩ 100Ω
4.000MΩ 1kΩ
±(2.0% + 10 digits)
40.00MΩ 10kΩ
Maximum Input: 600V DC or 600V AC RMS