TRIG —l—>
100
Press the TRIG softkey and
then use the arrow keys to
set the number of frames to
be saved before the trigger
signal is received.
If the REC TRIG mode is not selected the TRIG softkey window
will read NA and the keypad will beep if the TRIG softkey is
pressed.
The number of TRIG frames selected will be retained when the
power is off.
The TRIG softkey controls the number of frames recorded before
the TRIGGER IN signal is received. The number of frames re-
corded after the TRIGGER IN signal can be calculated as follows:
post-trigger frames = mf - (pre + 1)
mf (maximum frames) is the highest number of frames available
in the TRIG Softkey field.
pre (pre-trigger) is the number of frames selected in the TRIG
Softkey field.
The one accounts for frame zero which is assigned to the frame
being recorded when the trigger input signal is received.
The vertical line is a trigger position indicator. The left end of the
arrow represents the first available frame in memory. The right
end of the arrow represents the last available frame in memory
and tells you the total number of frames installed in the Proces-
sor. The trigger position indicator moves along the arrow to
provide a visual display of trigger positioning within available
memory.