EasyManua.ls Logo

Kodak Sidekick 1400u - Replacing Consumables; Replacing the Paper Feed Roller Module

Kodak Sidekick 1400u
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-6 A-61676 June 2010
Replacing
Consumables
Replace the paper feed roller module and the separation roller module
after 300,000 scans. Replace the roller modules more often if feeding
problems continue after cleaning (i.e., paper jamming, slipping, multi-
feeding, marking, etc.).
See “Supplies and consumables” later in this chapter for more
information regarding additional roller modules.
Replacing the paper feed
roller module
1. Turn the scanner off.
2. Push the ADF door release button to open the ADF door.
3. Open the new Roller Exchange Kit.
4. Push the two green levers down at both ends of the paper feed
roller module to unlock and remove the paper feed rollers.
NOTE: When moving the green levers, do not apply pressure in
any direction other than shown by the arrows.