Cooling system
u Place guiding rods in place of two screws 3.
u Place thermostat housing.
u Place screws 3.
u Remove guiding rods.
u Place remaining screws.
u Screw thermostat housing 2 with screws 3, 6.
u Tighten screws to torque according to tightening specifications.
Information
Vent coolant circuit at the end of installation.
Specific values
Thermostats LT start to open at 45 °C (113 °F) and are fully opened at 57 °C (135 °F).
Tightening specifications
Refer to standard tightening torques. (For more information see: 5.3 Standard tightening torques,
page 274.)
3.10.6 Coolant pump HT removal and installation (SL 216)
Previous tasks
q Drain HT coolant circuit.
q Remove machinery HT cooling system piping.
Specific safety instructions
NOTICE
Risk of property damage by reuse of sealing.
Leakage by faulty seal.
u Replace all sealings.
Special tools
Special tool Designation
Guiding rod M12x100 - Coolant pump (x2)
Tab. 49: Special tools
230
© 2021 by Kohler Co. All rights reserved.
KD83V16 33525088901_2_1 EN_US
2021-07

Table of Contents

Other manuals for Kohler KD83V16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD83V16 and is the answer not in the manual?

Kohler KD83V16 Specifications

General IconGeneral
BrandKohler
ModelKD83V16
CategoryEngine
LanguageEnglish

Related product manuals