EasyManuals Logo

Kohler KD83V16 User Manual

Kohler KD83V16
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
Operation and Maintenance Manual Appendix
Error code
SPN FMI Designation
1349 0 Common rail 2 - Critical overpressure
1240 2 Common rail 2 - Leakage
1349 15 Common rail 2 - Overpressure warning
516124 11 Common rail 2 - PCV opened due to overpressure
516125 11 Common rail 2 - Plausibility error of VCV current
516128 11 Common rail 2 - Pressure remains above the set point
516129 11 Common rail 2 - Pressure remains below the set point
516130 11 Common rail 2 - Start pressure too low
1239 0 Common rail leakage 1 - Fuel leak
1239 11 Common rail leakage 1 - Out of range
1239 31 Common rail leakage 1 - Supply voltage out of range
1240 0 Common rail leakage 2 - Fuel leak
1240 11 Common rail leakage 2 - Out of range
1240 31 Common rail leakage 2 - Supply voltage out of range
516131 11 Common rail pressure sensor - No signal variation
157 3 Common rail pressure sensor - Short circuit to battery or open
circuit
157 4 Common rail pressure sensor - Short circuit to ground
157 31 Common rail pressure sensor - Supply voltage out of range
516133 11 Common rail pressure sensor 2 - No signal variation
1349 3 Common rail pressure sensor 2 - Short circuit to battery or open
circuit
1349 4 Common rail pressure sensor 2 - Short circuit to ground
1349 31 Common rail pressure sensor 2 - Supply voltage out of range
2430 11 Coolant level sensor - Out of range
2430 3 Coolant level sensor - Short circuit to battery
2430 4 Coolant level sensor - Short circuit to ground or open circuit
2430 31 Coolant level sensor - Supply voltage out of range
6303 11 Coolant level sensor 2 - Out of range
6303 3 Coolant level sensor 2 - Short circuit to battery
6303 4 Coolant level sensor 2 - Short circuit to ground or open circuit
6303 31 Coolant level sensor 2 - Supply voltage out of range
6209 0 Coolant temperature at intercooler - Critical overtemperature
6209 15 Coolant temperature at intercooler - Overtemperature warning
110 5 Coolant temperature sensor - Open circuit
110 3 Coolant temperature sensor - Short circuit to battery
110 4 Coolant temperature sensor - Short circuit to ground
110 31 Coolant temperature sensor - Supply voltage out of range
KD83V16 33521030601_0_1 EN_US
2018-07
© 2018 by Kohler Co. All rights reserved.
147

Table of Contents

Other manuals for Kohler KD83V16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD83V16 and is the answer not in the manual?

Kohler KD83V16 Specifications

General IconGeneral
BrandKohler
ModelKD83V16
CategoryEngine
LanguageEnglish

Related product manuals