Appendix Operation and Maintenance Manual
Error code
SPN FMI Designation
101 0 Crankcase pressure - Critical overpressure
101 15 Crankcase pressure - Overpressure warning
101 31 Crankcase pressure - Supply voltage out of range
101 3 Crankcase pressure sensor - Short circuit to battery
101 4 Crankcase pressure sensor - Short circuit to ground or open
circuit
637 2 Crankshaft position - Plausibility error
637 14 Crankshaft position sensor - Ground error
637 5 Crankshaft position sensor - Open circuit
637 3 Crankshaft position sensor - Short circuit to battery
637 3 Crankshaft position sensor - Short circuit to battery or open circuit
637 4 Crankshaft position sensor - Short circuit to ground
637 31 Crankshaft position sensor - Supply voltage out of range
1136 0 ECU - Critical overtemperature
516543 31 ECU - Data recorder was triggered
1136 15 ECU - Overtemperature warning
516495 31 ECU - Runtime reached the maximal time without reset
1136 31 ECU temperature sensor 1 - Supply voltage out of range
516140 31 ECU temperature sensor 2 - Supply voltage out of range
516141 31 ECU temperature sensor 3 - Supply voltage out of range
51644 31 Engine - Starter activated but no engine rotation detected
516356 31 Engine control unit - Communication error to slave injection
control unit
639 5 Engine Control Unit CAN 1 - Open circuit
639 11 Engine Control Unit CAN 1 - Short circuit
625 5 Engine Control Unit CAN 2 - Open circuit
625 11 Engine Control Unit CAN 2 - Short circuit
516148 5 Engine Control Unit CAN 4 - Open circuit
516148 11 Engine Control Unit CAN 4 - Short circuit
110 0 Engine coolant - Critical overtemperature
111 17 Engine coolant - Level low
110 15 Engine coolant - Overtemperature warning
4076 14 Engine coolant 2 - Level low
175 0 Engine oil - Critical overtemperature
100 1 Engine oil - Critical underpressure
175 15 Engine oil - Overtemperature warning
100 2 Engine oil - Plausibility error
100 17 Engine oil - Underpressure warning
148
© 2018 by Kohler Co. All rights reserved.
KD83V16 33521030601_0_1 EN_US