Operation and Maintenance Manual Appendix
Error code
SPN FMI Designation
1180 2 Exhaust boost temperature (CMR sensor) - Communication error
1180 2 Exhaust boost temperature 1 (CMR sensor) - Communication
error
1181 2 Exhaust boost temperature 2 (CMR sensor) - Communication
error
3245 0 Exhaust temperature before turbocharger 1 - Critical overtemper-
ature
1180 15 Exhaust temperature before turbocharger 1 - Overtemperature
warning
3279 0 Exhaust temperature before turbocharger 2 - Critical overtemper-
ature
1181 15 Exhaust temperature before turbocharger 2 - Overtemperature
warning
94 0 Fuel supply - Critical overpressure
174 0 Fuel supply - Critical overtemperature
94 1 Fuel supply - Critical underpressure
174 15 Fuel supply - Overtemperature warning
94 3 Fuel supply pressure sensor - Short circuit to battery
94 4 Fuel supply pressure sensor - Short circuit to ground or open
circuit
94 31 Fuel supply pressure sensor - Supply voltage out of range
174 5 Fuel temperature sensor - Open circuit
174 3 Fuel temperature sensor - Short circuit to battery
174 4 Fuel temperature sensor - Short circuit to ground
174 31 Fuel temperature sensor - Supply voltage out of range
516195 2 Generator Set Controller - Communication error
190 0 Genset - Engine over speed
729 6 Heating flange 1 - Critical high output current
729 11 Heating flange 1 - Electrical error
729 5 Heating flange 1 - Open circuit
729 3 Heating flange 1 - Short circuit to battery high side
516304 3 Heating flange 1 - Short circuit to battery low side
729 4 Heating flange 1 - Short circuit to ground high side
516305 4 Heating flange 1 - Short circuit to ground low side
730 6 Heating flange 2 - Critical high output current
730 11 Heating flange 2 - Electrical error
730 5 Heating flange 2 - Open circuit
730 3 Heating flange 2 - Short circuit to battery high side
516344 3 Heating flange 2 - Short circuit to battery low side
730 4 Heating flange 2 - Short circuit to ground high side
KD83V16 33521030601_0_1 EN_US
2018-07
© 2018 by Kohler Co. All rights reserved.
149