SC200 Installation& Operation Manual 3-16
11
Water Plate Closure Problems:If the water plate is not able to close due to ice remaining on the
water plate surface, the plate will reopen until it is clear.
Shutdown-High Pressure:All models are provided with a high pressure cutoff, which interrupts
power to the compressor and to the condenser fan motor, if so equipped, when the high-side
pressure rises to the cutoff setting. The high pressure cutoff will automatically reset, restoring
power when the pressure drops. When this happens it is important to determine the cause of the
high pressure and correct it.