SC200 Installation& Operation Manual 3-16
6
Electrical
WARNING: Failure to comply with these regulations may cause serious injury or death
and cause damage to the machine and its surroundings.
CAUTION: Switching the machine “off” does not de-energize all circuits. Always disconnect
power before servicing.
All KOLD-DRAFT models are intended to be installed with a permanent connection to the field
electrical supply. See rating plate on the back of the machine for power supply requirements.
Each ice maker must be connected to a separate protected circuit with no other loads.
Fused disconnects, installed adjacent to each ice maker, are recommended and may be
required by local codes. These components must be supplied by the installer.
Electrical service must fall within the voltage tolerances listed below:
Maximum Overload Protection must be no greater than specified. The minimum circuit
ampacity specified does not indicate a typical running current value. Use the minimum
ampacity value for sizing branch circuit conductorsup to 26 feet (8 meters) in length. For a
conductor length over this length, increase the wire gauge as required by code.
Ice Cube Information
Cube Type
Cube Dimensions
Cube Weight
Cubes per Cycle
C (Full Cube)
1-1/4 x 1-1/4 x 1-1/4 in (32 x 32 x 32 mm)
1.15 oz (32.6 g)
45
Model
Nominal (V)
SC201
115
SC204
208-230
SC207
230