Torque range: 0.35-70 Nm
UIDENTIFICATION DATA OF THE MANUFACTURER
KOLVER S.r.l.
VIA M. CORNER, 19/21
36016 THIENE (VI) ITALIA
UIDENTIFICATION DATA OF THE PRODUCT
MODEL: EDU 2AE/TOP EDU2AE/TOP/E EDU2AE/TOP/TA
CODE: 032000/TOP 032000/TOP/E 032000/TOP/TA
TECHNICAL DATA OF THE PRODUCT
FUSE: 3,15 A
DIMENSIONS: 190 x 205 x h120 mm WEIGHT: 2,5 Kg
DECLARATION OF CONFORMITY
KOLVER S.r.l. declares that the new tool here described: control unit model EDU2AE/TOP and
EDU2AE/TOP/TA is in conformity with the following standards and other normative documents:
2006/42/CE, LVD 2014/35/UE, EMCD 2014/30/UE, EN 62841-2-2:2014, EN 62841-1: 2015, EN 60204-1,
EN 61000-6-2, EN 61000-6-4.
It is also in conformity with RoHS III normative (2011/65/UE and following 2015/863).
Name: Giovanni Colasante
Position: General Manager
Person authorized to compile the technical file in Kolver
Thiene, January 1
st
2021
Giovanni Colasante

Questions and Answers

  • S
    swoodSep 2, 2025
    What to do if Kolver EDU 2AE/TOP/TA displays “Error missing piece”?
    • B
      Brian HicksSep 2, 2025
      If your Kolver Control Unit displays “Error missing piece”, it indicates that the “missing piece” contact is enabled. To address this, check contact 2 on the CN2 connector.
  • T
    Tracy RobertsonSep 2, 2025
    What to do if Kolver EDU 2AE/TOP/TA Control Unit displays “tightened screw”?
    • J
      Jennifer WhitneySep 2, 2025
      If your Kolver Control Unit displays “tightened screw” on the status bar, and the torque signal is displayed during the motor startup process (which lasts 0.3 seconds), you should check the parameters again.
  • M
    martinlorraineSep 3, 2025
    How to fix Kolver EDU 2AE/TOP/TA Control Unit when “waiting connection” doesn’t turn into “system ready”?
    • B
      bakerjohnSep 3, 2025
      If your Kolver Control Unit displays “waiting connection” and does not switch to “system ready” after being turned on, check the flat connector inside the unit.
  • C
    Crystal StewartSep 3, 2025
    What to do if my Kolver Controller shows “Output Disabled”?
    • A
      alisha98Sep 4, 2025
      If the Kolver Controller displays 'Output Disabled', it means the protection of output signals was activated because the maximum load (400mA) was exceeded. To resolve this, verify that the set load does not surpass the maximum allowed value. Then, restart the control unit to reset the error.
  • C
    Cameron JordanSep 4, 2025
    What does “Protection 15A” mean on my Kolver Controller?
    • M
      Michael OwensSep 4, 2025
      If the Kolver Controller displays “Protection 15A”, it indicates that the current on the mosfets of bridge H exceeded 15A for at least 500ms. To address this: - Decrease the screwing time and check the settings. - Avoid motor stalling. - Ensure unscrewing isn't too heavy. - Check if the joint is too soft.
  • A
    Amy HarrellSep 5, 2025
    What causes “Protection 14p5A” error on the Kolver Controller?
    • V
      villarrealrichardSep 5, 2025
      The “Protection 14p5A” error on the Kolver Controller indicates that the current on the mosfets of bridge H is greater than 14.5A for at least 800ms. Suggested solutions include decreasing the screwing time, checking settings, avoiding motor stalling, ensuring unscrewing isn't too heavy, and verifying the joint isn't too soft.
  • P
    Phillip CarlsonSep 5, 2025
    How to fix “Protection 12A” error on a Kolver Controller?
    • K
      Kyle PadillaSep 5, 2025
      If the Kolver Controller displays “Protection 12A”, it means the current on the mosfets of bridge H is greater than 12A for at least 1 second. You should decrease the screwing time and check the settings, avoid motor stalling, ensure unscrewing isn't too heavy, and verify the joint isn't too soft.
  • R
    Rickey YoungSep 6, 2025
    What to do if Kolver Controller shows “Error Torque Control”?
    • M
      Michelle FieldsSep 6, 2025
      If the Kolver Controller displays “Error Torque Control”, make a new screw. If the error persists, change the torque and speed settings.
  • A
    April CamachoSep 7, 2025
    Why does my Kolver Controller display "Torque / Speed Error" in Unit mode?
    • J
      Jennifer SchroederSep 7, 2025
      If the Kolver Controller displays "Torque / Speed Error" in Unit mode, it means a torque or speed has been set which is not included in the table relating to the selected screwdriver. Set a torque or speed value included in the range indicated in the table to resolve this issue.