3.2. Control panel C6.2
Simple and user-friendly control panel for intuitive navigation and control of the unit. This control panel oers 4 standard
operation modes (see Chapter 2.2) and switching ON/OFF with a touch of a button without any additional settings (settings
are pre-set in the factory). This control panel is recommended for application when the user is not allowed to change any
device settings or air temperature (for example, in the children’s room). To change operating settings you will have to con-
nect a C6.1 control panel, computer or smart phone to the unit.
ECO
function button
AWAY
operation mode
INTENSIVE
operation mode
NORMAL
operation mode
BOOST
operation mode
AUTO function
button
ON/OFF
button
Reset
button
Message indicator
(red)
Indicators of active
operation modes (blue)
Stopped unit indicator
(red)
3.2.1. Turning on/o and changing operation modes
Red indication lamp lights up near the ON/OFF button if the unit is connected to the mains and currently is stopped.
To turn on/o the unit or to select an operation mode:
1. Press a button of a desired operation mode and the unit will start working.
2. A blue indicator light will turn on near the activated operation mode.
3. To turn o the device, press the ON/OFF button.
4. Once the unit is stopped, a red indicator light will turn on near the ON/OFF button.
3.2.2. Messages
In case of any fault messages during operation of the unit, a red indication lamp will light up near the reset button. De-
pending on the message type, the indicator may light up or blink (see Chapter “Troubleshooting”). To delete the message,
press and hold the reset button for 5 seconds.
3.2.3. Control panel sounds
When a message appears, the control panel noties the user with a beep. You may temporarily disable an audible alarm
by pressing the reset button or deleting a fault message.
To disable audible alarms perform the following:
1. Press the ON/OFF button and hold for 5 seconds until you hear a beep and a red indicator light starts blinking.
2. If you hear a fault alarm and the reset button lights up in red, briey press the reset button to turn o an audible
alarm.
3. If the fault alarm is not audible and the reset indicator does not light up, briey press the reset button to turn on an
audible alarm.
4. To save your changes, press the ON/OFF button and hold it for 5 seconds until you hear a beep. Briey press the ON/
OFF button to return without saving.