EasyManua.ls Logo

Korber Solutions LTI MOTION ServoOne CM - Overview of the Connections

Default Icon
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Electrical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
Abbreviation Designation Details
X1/ DC Link DC link supply via terminals
Only on model SO CM-E.x0xx.1/(2) add.
connections for second expansion
module
X2/ 24 V DC 24 V control supply via terminal
See Chapter 4.8
DC Link -/+ DC link supply busbars
See Chapter 4.6.3
24 V DC Control supply busbars
See Chapter 4.6.1
LEDs Error / Voltage
See Chapter 5.1
X3/ XC IN Cross-communication input
See Chapter 4.10
X4/ XC OUT Cross-communication output
X5/ REL Output Relay contact (RO02) programmable
See Chapter 4.9.2
X6/ State
Digital inputs (programmable)
Test pulse outputs
See Chapter 4.9.3
X7/ ES "Internal" quick shutdown
See Chapter 4.9.2
F+ = right
F- = left
Fuses for DC link cable protection
See Chapter 4.7
A Service cover
Connection for protective earth conductor/
earthing
See Chapter 4.4
Table 4.2 Key to the SO CM-E module layout
4.3 Overview of the connections
In the following you will nd the layout for the ServoOne CM-E expansion module with
the corresponding positions of the connectors and terminals.
24 V DC
DC Link +/-
X1/ DC Link
X2/ 24V DC
X3
X4
X6/State
X7/ES
F-
F+
A
X5/REL
LEDs
Figure 4.1 Layout, ServoOne CM-E expansion module

Table of Contents