23
Electrical installation
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
4.6.5 Overview of busbars in the group
A
Figure 4.8 Cover on the busbars
WARNING! Risk of injury due to electrical power!
Carelessness may result in serious injuries or death.
The multi-axis system is only allowed to be operated with the cover on the busbars closed! It
is also important that the side covers (A) are tted. Both provide protection against physical
contact with bare and live parts.
4.6.4 Power supply, "Dual End" model
Figure Key
5. 6.
X1
4.
4. DC link power supply from the 1st expansion
module type "Dual" to terminal X1
5. SO CM-E expansion module "Dual End"
6. SO CM axis controller BG1
NOTE:
The 24 V DC busbar ttings
are to be tightened to a
torque of 2.1Nm.
Pre-assembled DC link
cable, see Chapter A.5.2
Figure 4.7 Busbars, DC link power supply (type "Dual End")