31
Appendix
Operation Manual Expansion Module SO CM-E
1800.202B.0-01 Date: 02/2019
A Appendix
NOTE:
Until the type test is completed, all technical data are only calculated values
and not assured characteristics.
A.1 Technical data, SO CM-E
ServoOne CM-E expansion module Unit
SO CM-E.x0xx.0 (2)
Single + (Dual End)
SO CM-E.x0xx.1
Dual
Control section
Supply voltage +/- 10% V DC 24 24
Rated current consumption A 0.25 0.25
Power dissipation W 6.0 6.0
DC link (input = left, output = right side of device)
Input voltage 1) V DC 565 to 678 565 to 678
Input current A DC 39 to 33 78 to 64
Output voltage 1) V DC 565 to 678 565 to 678
Output current A DC 39 to 33 2 x 39 to 2x 32
Power section
Continuous power P
N
kW 22 44
Peak power 2 x P
N
for 1 s kW 44 88
Power dissipation in the interior W 20 20
1) The voltage is dependent on the supply unit SO CM-P and the supply voltage connected (3x400/480 V AC)
Table A.1 Technical data, SO CM-E expansion module
A.2 Ambient conditions
Ambient conditions ServoOne CM-E expansion module
Protection Device: IP20 - exception terminals: IP00
Accident prevention regulations As per the local regulations (in Germany e.g. DGUV V3)
Installation altitude
Up to 1000 m aboveMSL, higher with power reduction
(1% per 100m, max. 2000m abovesea level)
Pollution degree 2 (as per EN 60664-1)
Type of mounting
Built-in unit, only for vertical mounting in a switch cabinet with min. IP4x
protection, on using STO safety function min. IP54
Table A.2 Ambient conditions, ServoOne CM-E expansion module
Climatic conditions ServoOne CM-E expansion module
In transit
As per EN61800-2, IEC60721-3-2 class 2K3
1)
Temperature -25°C to +70°C
Relative atmospheric
humidity
95% at max. +40°C
In storage
As per EN61800-2, IEC60721-3-1 classes 1K3 and 1K4
2)
Temperature -25°C to +55°C
Relative atmospheric
humidity
5 to 95%
In operation
As per EN61800-2, IEC60721-3-3 class 3K3
3)
Temperature 5°C to +40°C (4, 8, 16kHz), to 55°C with power reduction
Relative atmospheric
humidity
5 to 85% without condensation
1) The absolute humidity is limited to max. 60 g/m³. This means, at 70°C for example, that the relative atmospheric humidity may only be max. 40%.
2) The absolute humidity is limited to max. 29 g/m³. So the maximum values for temperature and relative atmospheric humidity stipulated in the table must
not occur simultaneously.
3) The absolute humidity is limited to max. 25g/m³. That means that the maximum values for temperature and relative atmospheric humidity stipulated in
the table must not occur simultaneously.
Table A.3 Climatic conditions, ServoOne CM-E expansion module