Operating instructions
KRAL screw pumps.
Series C / Type CGF/CGH/CGV/CLE
Mechanical seal/Radial shaft seal
OIC 18en-GB
Edition 2020-01
Original instructions
www.kral.at

Table of Contents

Questions and Answers

  • D
    David CalhounSep 16, 2025
    What should I do if my KRAL Water Pump has too little pumped liquid?
    • W
      Walter SmithSep 16, 2025
      If your KRAL Water Pump isn't pumping enough liquid, the solution is to fill the pump with the pumped liquid.
  • C
    Charles JonesSep 18, 2025
    What to do if my KRAL C Series does not vent?
    • W
      William WeaverSep 18, 2025
      If your KRAL Water Pump isn't venting properly, vent the pressure line at the highest point.
  • S
    Samuel MurphySep 18, 2025
    What to do if my KRAL C Series has an incorrect pump direction of rotation?
    • R
      robersonmichaelaSep 18, 2025
      To correct the rotation, swop the two electrical connection phases.
  • J
    Jose CisnerosSep 22, 2025
    What should I do if the shaft seal of my KRAL C Series Water Pump is overloaded?
    • G
      Gregory MorganSep 22, 2025
      If the shaft seal of your KRAL Water Pump is overloaded through thermal or chemical influences: 1. Check the maximum operating temperature. 2. Check the suitability and resistance of the elastomers with regard to the pumped liquid.
  • D
    dleeSep 23, 2025
    What to do if my KRAL Water Pump's inlet pressure is too high?
    • D
      Donald AdamsSep 23, 2025
      If the inlet pressure of your KRAL Water Pump is too high, reduce the inlet pressure at the system side.
  • P
    Patricia DavisSep 23, 2025
    How to fix a cold start when delivering high-viscosity liquids with my KRAL Water Pump?
    • J
      Joan DukeSep 23, 2025
      To resolve cold start issues when delivering high-viscosity liquids, install the heating system.
  • P
    Paul AndrewsSep 23, 2025
    What to do if my KRAL C Series Water Pump has an overload of the shaft seal by pressure build-up during the heating process?
    • A
      Ashley CarterSep 23, 2025
      If the shaft seal is overloaded due to pressure build-up during heating, open the pressure-side/suction-side shut-off device in order to avoid a pressure build-up through heat expansion of the pumped liquid.
  • C
    charles35Aug 31, 2025
    What to do if the viscosity of the pumped liquid is too high in my KRAL Water Pump?
    • J
      Jason LeeAug 31, 2025
      If the viscosity of the pumped liquid is too high in your KRAL Water Pump, increase the temperature of the liquid or reduce the rotation speed.
  • D
    Diana GarciaAug 25, 2025
    What to do if my KRAL Water Pump filter or strainer is soiled?
    • K
      keithhendersonAug 25, 2025
      If the filter or strainer of your KRAL Water Pump is soiled, clean the filter or strainer.
  • E
    Elizabeth RobinsonAug 26, 2025
    What to do if my KRAL C Series Water Pump has incorrect pump direction of rotation?
    • M
      Michael CaseyAug 26, 2025
      If your KRAL Water Pump has an incorrect direction of rotation, make the electrical connection such that the direction of pump rotation matches that of the arrow on the flange cover.