2. Do either of the following:
• Click Download to either open the file or save it to the required
location
—OR—
• Click OK to complete the procedure
Note: If the Authentication page is left open for more than five minutes an
additional windows may open. After entering your logon credentials, close the
other windows.
8.3.3 Resetting to Factory Default Parameters
To reset the TP-590Rxr to factory default parameters:
1. Click the Factory reset button.
The confirmation message is displayed.
2. Click OK to continue or Cancel to exit the procedure.
8.4 The EDID Management Page
The EDID Management page lets you copy EDID data to either or both of the
inputs from the following sources:
• Output
• Input
• Default EDID
• EDID data file
From this page you can also lock the EDID on each input independently.
Note: Do not power up the display before locking the EDID.