VIA Campus - Using VIA Campus
61
· Manage the following statuses for all Campus/Connect units attached to the
VSMS:
§ CPU usage
§ HDD usage
§ Off/on status
§ Configuration and download status
§ Version status
The VSMS can automatically provide individual configuration to added gateways or
the settings can be configured locally.
Some changes must be made to the gateway before it can be managed from a VIA
Site Management Server.
1. Type the VIA Site Management Server IP.
2. Type a Gateway ID (a gateway ID can be a random number, as long as it is
unique. It helps identify the VIA Campus or Connect unit in question.)
3. Click Validate and Save for changes to take effect.
4. Choose the settings “From HQ” to download the setting from the HQ server
or choose “From Gateway” to keep the local settings.
5. Click Reboot to restart the unit.