39
DISPLAY?
Command Name
Permission
Transparency
Set:
-
-
-
Get
DISPLAY?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get output HPD status
#DISPLAY?out_id
Response
~ nn@DISPLAYout_id,status ␍␊
Parameters
out_id - output number
status - HPD status according to signal validation
Response Triggers
After execution, response is sent to the com port from which the Get was received
Response is sent after every change in output HPD status ON to OFF
Response is sent after every change in output HPD status OFF to ON and ALL parameters (new EDID,
etc.) are stable and valid
Notes
DPSW-STATUS?
Command Name
Permission
Transparency
Set:
-
-
-
Get:
DPSW-STATUS?
End User
Public
Description
Syntax
Set:
-
-
Get :
Get the DIP-switch state
# DPSW-STATUS? dp_sw_id
Response
~nn @ DPSW-STATUS? dp_sw_id, status␍␊
Parameters
dp_sw_id - 1….num of DIP switches
status - 0: up
1: down
Response Triggers
Notes