VM-214DT Operating the VM-214DT Remotely Using the Web Pages
19
The Data Switching Page
The Data Switching page lets you route the RS-232 and IR inputs and outputs.
Figure 18: The Data Switching Page
#
Item
Description
1
RS-232
Switching area
2
Input 2 selection
row
Click a box to enable the routing of RS-232 data from Input
2 to the selected output(s)
3
RS-232 data
selection row
Click a box to enable the routing of RS-232 data from the
RS-232 Data port to the selected output(s)
4
IR Switching
area
5
IR modulation
indicator
Indicates whether IR modulation is enabled or disabled
6
Input 2 selection
row
Click a box to enable the routing of IR data from Input 2 to
the selected output(s)
7
Remote IR
selection row
Click a box to enable the routing of IR data from the IR
sensor on the front panel to the selected output(s)
RS-232 Switching Example
In the example configuration shown in Figure 19 RS-232 data is routed from the RS-232 Data
3-pin terminal block to the HDBT Output 3.