EasyManua.ls Logo

Krober O2 - Removing the Camozzi Functional Unit

Krober O2
93 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kröber O2
Service work
12
3.3.2 Removing the Camozzi functional unit
1. Disconnect the red connector of
the valve control line from the
control board.
2. Loosen the cable tie on the EMC
core with side cutters.
NOTE!
It is normal that a slight popping
noise may occur due to any
excess pressure still present in
the hose.
3. Press the edge of the plug-in
connection at the air inlet of the
functional unit down evenly and
pull out the hose.