PROBLEM CAUSE SOLUTION
The portalter cannot be
inserted to the brewing head.
The ground coee has not
been tamped correctly or the
quantity is excessive.
Refer to the Tamping section
in the user manual.
Put less ground coee in the
lter.
The machine fails to produce
espresso or very little
epsresso comes out.
No water in the tank,(The lack
of water light is ashing).
Fill the tank (2).
Water in the tank was running
out during the brewing.
Fill the tank. The launched
recipe will resume (2).
The water tank is not properly
in place and the valves at the
bottom are not open.
Press down lightly on the
tank to open the valves at the
bottom.
Coee ground too nely. Adjust the grinding level to
coaser (13).
Too much ground coee. Reduce the ground coee
quantity (15).
Coe ground tamped too
strongly
Reduce the tamping force.
Limescale in the water circuit. Descale the machine as
described in the user manual.
The espresso coee drips
from the edges of the
portalter instead of from the
holes.
The portalter is not correctly
in place.
Insert the portalter
correctly(25).
The coee spout gasket has
lost exibility or is dirty.
Contact a customer services
center to have it replaced.
Blockage in the coee lter. - Rinse the lter under
running water.
- Adjust the grinding settings
to coarser (13).
The espresso crema is too
thin, pale and delivered from
the spout too fast.
The machine settings are not
appropriate.
See instructions in section
“Adjust your espresso results”
in the user manual.
The espresso crema is too
dark and spotty (delivered
from the spout too low).
The machine settings are not
appropriate.
See instructions in section
“Adjust your espresso results”
in the user manual.
My coee is not hot enough. Machine is not heated
enough.
See instructions in section
“Adjust your espresso results”
in the user manual.
Coee preparation
temperature setting is low.
See instructions in section
“Adjust your espresso results”
in the user manual.
PROBLEM CAUSE SOLUTION
There is water in the drip tray. This water comes from
the internal circuits of the
machine and is a normal
consequence of their
operation.
Empty and clean the drip tray
on a regular basis (48).
After making 1st coee, I
can’t launch 2nd coee coee
just after.
Machine needs around
30seconds between the
cups in order to ensure good
temperature of coee.
You can use the grinder
during this waiting time.
Manometer doesn’t move. Coee brewing pressure is
too low.
To increase the pressure,
(1) Grinder ner (13)
(2) Increase the ground coee
quantity
(3) Tamp stronger.
I don’t nd Tamping station. Tamping station (& KRUPS
branded towel) comes only
with Precision+ (XP804T).
I can’t choose ‘1 CUP or
2CUP’, ‘Preinfusion time’ nor
‘Temperature’.
Either Hot water function,
Steam function or CALC is
chosen.
Select coee recipes
(Espresso, Lungo, Americano).
Not possible to change
the temperature for these
functions (52).
If it is not possible to determine the cause of the fault, consult an approved service centre. Never
disassemble the appliance! (if the appliance is disassembled, this will void the guarantee).
ELECTRICAL OR ELECTRONIC PRODUCT END OF LIFE
We participate in the protection of the environment!
Your product contains a number of materials that can be reused recycled.
Take it to a collection point or an approved service centre so that it can be
dealt with appropriately.