k
d
2
number of
holes n
Mating flange
All flanges designed as plate flanges
Omega
65
Standard flange connections
1)
:
Pump
Size
JL 1040 / GGG--NiCrNb 202
Nominal pressure acc. to:
JS 1030 / 1.4517
Nominal pressure acc. to:
DIN 2501
ISO 7005/2
BS 4504 ANSI B 16.1 DIN 2501
ISO 7005/2
BS 4504 ANSI B 16.1
80-210
80-270
80-370
100-250
a
e
ass
5
5
a
e
5
ass
5
100-310
100-375
1)
Other flange connections on request
Flange dimensions -- Hole pattern All dimensions in mm
Standard
Suction flange Discharge flange
DN d
2
k n DN d
2
k n
Pump sizes 80-210 up to 80-370 125 80
ISO 7005/2
DIN 2501
BS 4504
PN 16
Table 16/11
19 (M16) 210
ISO 7005/2
DIN 2501
BS 4504
PN 25
Table 25/11
28 (M24) 220
8
8
ANSI B 16.1 Class 250 23 (M20) 235 23 (M20) 168
Pump sizes 100-250 up to
100-375
150 100
ISO 7005/2
DIN 2501
BS 4504
PN 16
Table 16/11
23 (M20) 240
19 (M16) 180
ISO 7005/2
DIN 2501
BS 4504
PN 25
Table 25/11
28 (M24) 250
23 (M20) 190
8
ANSI B 16.1 Class 250 23 (M20) 270
12
23 (M20) 200
Baseplate / motor combinations
Pump
Motor Size
Size
100L 112M 132S 132M 160M 160L 180M 180L 200L 225S 225M 250M 280S 280M 315S 315M 315L 315
No of
poles
4 4 4 4 2 4 2 4 2 4 4 2 4 4 2 4 2 4 2 2 2 2 2 2
80-210 1 1 1 1 1 1 1 1 2 2
80-270 1 1 1 1 1 1 1 1 1 1 2 2 2 2 3
80-370 1 1 1 1 1 1 1
100-250 1 1 1 1 1 1 1 1 1 2 2 2 2 3 3
100-310 1 1 1 1 1 1 1 1 2 2 2 2 3 3 3 3
100-375 1 1 1 1 1 2 2 2
N.B.: - The numbers listed in the table indicate the relevant baseplate numbers.
- The baseplate numbers shown in the boxes also serve to select the correct motor size for the listed pump size.
- Units comprising a motor size 315 and larger are completely assembled for verification and adjustment of the individual
components. Before shipment, the units are dismantled again and the components packed / shipped separately