60 Hz Submersible Borehole Pumps
98
Typical Tender for UPA 300, 350
No. Qty Item
Unit price Amount
Submersible borehole pump(s) type UPA 300 / 350
1)
for well diameters of 300 mm (12 in ches) and above.
Make: KSB
Pump + motor: UPA -- / +
Multistage centrifugal pump in ring-section design for vertical / horizontal
1)
installa-
tion. Mixed flow hydraulic systems with impellers that can be turned down. Pump
bearing lubricated by the fluid handled and protected against ingress of sand. Inte-
grated check valve with anti-blockage, spring-loaded valve disc / connection
branch. Pump end with internal thread / flange
1)
. Suction casing with suction strainer
fitted between pump and motor.
Pre-filled submersible motor. Three-phase current. Squirrel-cage design with self-
aligning thrust bearing and adequately sized expansion diaphragm for pressure
equalization. Design in compliance with VDE standards. IP 68 enclosure. With power
supply cables. Required flow velocity past the motor: v ≥ 0.5 m/s.
Fluid handled: clean to slightly contaminated water, slightly aggressive / more
aggressive / as specified in water analysis
1)
, with a permissible
sandcontentofupto50g/m
3
.
Casings cast iron / bronze
1)
.....................................
Impellers bronze....................................
Wear rings bronze..................................
Shaft (pump + motor) Chrome / CrNiMo steel
1)
.........................
Stator case (motor) CrNiMo steel...........................
Bolts, screws and nuts CrNiMo steel (A4)........................
Capacity Q =
m
3
/h / l/s.....................
Head H =
m........................
Shut-off head H
o
= m.................
Efficiency η Pump
%/Motor %....................
Temperature (fluid handled) t =
°
C.....
Rated power / amperage P
N
= hp / I
N
= A.......
Speed / Frequency n ≈
rpm/f= Hz............
Supply voltage U =
V................
Starting d.o.l. / star-delta
1)
.........................
Pump end G6’’ / G8’’ / DN 150 / DN 200 / DN 250
1)
....................
Outside diameter D
max
= mm..............
Economic efficiency analysis (for ex. for 10 years):
Operating period per year approx.
h/
Electricity costs
/kWh. Pump data tolerances to ISO 9906 Class 1.
During the acceptance test, the overall efficiency may be max. 3 percentage points
lower than the overall efficiency quoted (η ”pump” x η ”motor”).
Pair of supporting and installation clamps for riser R / DN
1)
. .
Set of bearing pedestals for horizontal installation without / with
1)
water storage tank.
Power supply cable, separate / connected
1)
, mm
2
, m length.
Cable connector, size
, with sealing compound, motor supply not connected
and sealed / connected and sealed
1)
at the factory.
Cable tie,size
.
Dry running protection equipment
-- f o r semi-automatic operation with 2
1)
-- f o r fully automatic operation with 3
1)
control current lines with a length of m each.
Temperature monitoring equipment Pt 100 for use in submersible motors to protect the
windings from overheating; it consists of a resistance thermometer with measuring line and
does not include / includes
1)
a display relay.
Sum total
1)
Delete as applicable