EasyManua.ls Logo

Kyocera Ecosys FS-1320D - 3.6.17 Code 39 (3 of 9)

Kyocera Ecosys FS-1320D
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.6.17 Code 39 (3 of 9) without space character
Type / properties:
Linear code
Activation sequence:
<Esc>(s24670T<Base Data><Stop Character>
For an explanation on selecting the stop character and the optional parameters, see
chapters 3.2.1. and 3.2.6.
Default - parameters:
v parameter 29
p parameter 1
b parameter 6,18
Additional properties:
Size of base data: 1 to 100
Character set: 0 to 9, A to Z, a to z, $ % + - . / Space
Example:
<Esc>(s24670T1234567890ABC<CR>
81

Table of Contents

Other manuals for Kyocera Ecosys FS-1320D

Related product manuals