3.6.21 Code 39 Extended
Type / properties:
Linear code
Activation sequence:
<Esc>(s24680T<Base Data><Stop Character>
For an explanation on selecting the stop character and the optional parameters, see
chapters 3.2.1. and 3.2.6.
Default - parameters:
v parameter 29
p parameter 1
b parameter 6,18
Additional properties:
Size of base data: 1 to 100
Character set: All printable characters from ASCII 00 to 127
Example:
<Esc>(s24680T 1234567890abc<CR>