EasyManua.ls Logo

Kyocera FS-920 - Printer Maintenance and Repair; Assembly;Disassembly Precautions and Procedures

Kyocera FS-920
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2GL/2FV/2FW
1-6-1
1-6 Assemb ly and Disassembly
1-6-1 Precautions for assembly and disassembly
(1) Precautions
Be sure to turn the power switch off and disconnect the power plug before starting disassembly.
When handling PWBs (printed wiring boards), do not touch parts with bare hands. The PWBs are susceptible to static
charge.
Do not touch any PWB containing ICs with bare hands or any object prone to static charge.
Use only the specified parts to replace the fuser thermostat. Never substitute electric wires, as the printer may be seriously
damaged.
Use the following circuit testers when measuring voltages:
Hioki 3200
Sanwa MD-180C
Sanwa YX-360TR
Beckman TECH300
Beckman DM45
Beckman 330 (Capable of measuring RMS values.)
Beckman 3030 (Capable of measuring RMS values.)
Beckman DM850 (Capable of measuring RMS values.)
Fluke 8060A (Capable of measuring RMS values.)
Arlec DMM1050
Arlec YF1030C

Related product manuals