2GL/2FV/2FW
1-6-9
1-6-5 Fuser unit
(1) Detaching and refitting the fuser unit
<Procedure>
1. Remove the outer covers. See page 1-6-2.
2. Remove the two connectors.
3. Remove the wire from two clamps.
Figure 1-6-12
4. Pull out the rear cover axis (with spring)
from the axis hole () on side.
5. Pull out the rear cover axis from the axis
hole () on side and remove the rear cover
and the spring.
Figure 1-6-13
Connector
Clamp
Clamp
Wire
Connector
Spring
Spring
Rear cover
Axis
Axis hole
Axis
Axis hole