To Previous Page IconTo Previous Page
Loading...
2PZ-3
1-5-33
8. Remove the screw and then remove the
fuser wire cover.
Figure 1-5-48
9. Remove the high voltage PWB.
(see page1-5-39)
10. Remove five screws.
11. While sliding the toner container
detection holder frontward, remove the
part A of controller shield and then
remove the part B.
*: When reattached, insert part A and part B
in the reverse order.
(First, insert the part B and then attach
the part A.)
Figure 1-5-49
Screw
Fuser wire cover
Controller
shield
Screw
Screw
Screw
Screw
Screw