(1) Detaching and refitting the laser scanner unit
Procedure
1. Remove the intermediate transfer unit
(see page 1-5-23).
2. Remove drum units (K, M, C, Y) and
developing units (K, M, C, Y) (see page
1-5-22, 20).
3. Remove the rear upper cover, right
upper cover, left upper cover and front
cover (see page 1-5-3).
4. Remove the left rear cover and left
cover (see page 1-5-10).
5. Remove two connectors (YC32, YC32)
from engine PWB.
Figure 1-5-75
6. Draw two connectors (YC31, YC32)
into the machine inside.
Figure 1-5-76
YC31
YC32
Engine PWB
Engine PWB
Connectors
(YC31,YC32)