2PZ-3
1-5-36
(Notes when reconnected)
1. Don't align the wires of the connectors
(YC37, YC40, YC38 and YC39) at the
main PWB front side at the lowerside than
the rib of the wire holder at the power
source PWB side.
OK: Align the wires at the upside than the
rib
NG: The wires are at the lower side than
the rib
Figure 1-5-54
2. After reattached, check the USB wire
(YC107 and YC108) is aligned at the upper
side than the rail for installing the optional
PWB at the backside of the controller fan.
3. The ferrite core of the USB wire connected
to YC100 is at the upside of the wire
holder.
4. The ferrite core of the USB wire connected
to YC108 does not contact the neighboring
mounted items on the board.
Figure 1-5-55
Wires
Rib
Ferrite core
Ferrite core
USB wire
Rail
Wire holder