2PZ-1
1-5-69
41. Disconnect the FFC wire at the connec-
tor YC8 on the main PWB.
*: Reconnect the connectors on the main
PWB before reattaching the wire holder
detached at Step 40.
Figure 1-5-112
42. Remove the wire holder and the ferrite
core.
Figure 1-5-113
43. Reattach the left and right holders in a
reverse manner of removal at Step 20,
21.
Close the Document Processor and the
scanner unit.
FFC wire
YC8
FFC wire
(Upper side of the main PWB)
Ferrite
core
Wire holder